Assembly

mainIMG.jpg

Our bars allow self-assembly without the need to lean out the window. The connections of the bars are made before the bar and are attached to the window frames and to the sill. For an additional fee it is possible to invite a professional person to install the bars (see price list). Bars installation instructions: Click here for installation presentation: 

It is obliged to read the installation instructions until the end including safety instructions before beginning the installation.

Tools needed:
• Home Drill (preferably vibrating)
• 6 mm concrete drill
• Phillips screwdriver
• 7 mm flat key (or key cup)
• Hammer
• Rope about 3 feet in length.

Install the two latches on the bottom and the rod second from bottom, (the lower pole of beam hardening) adjacent to the extreme vertical bars but to tighten it latches move freely on the rod (turning inward).

Remove the bar from the window by moving diagonally (after you connected it with a rope to a stable point in the room). Place the bar on the sill when the beam hardening at the bottom and stands on the outside, snap to the outside wall (by stretching the rope).

Slide and snap the latch that you have connected to the window frame when he was a bar surface and mark the place of the hole. Repeat the same operation for the second latch.

Drill a hole perpendicular to the frame, at the marked spots to a depth of at least 5 cm

Insert the dibble, using the hammer until the head will be totally swallowed into the wall.

Screw the screw until latch will be fixed in place. Tighten the nuts of the U connector with the flat key (7 mm). At this point the grille is firmly connected into place and there is no need to keep holding it (you may let go of the rope)

Install the two latches on the top perch visible through the window, and repeat Steps 3-6 you have already performed.


Safety:: 
• Do not drill holes in the brackets located less than 3.5 cm from the end frame.
• It is obliged to tie the bar with a rope during installation to prevent accidental fall.
• In the case of building blocks such as “Ytong” or other “easy to use” blocks it is obliged to use dibbles suitable for this construction.
• If the height of the window above the level of the bar - the margin with no bar should not exceed 10 cm, and in this case it must be connected to the upper steel pole brackets.
• The bar should be attached to the exterior wall. It is forbidden to stabilize the bars spacing from the wall.
• Do not use bars as a ladder, hang on it or hook up clotheslines, window boxes and the like.
• Do not use the bars as railings.
• It is required to install the bar with all eight latches.
• It is recommended to check the bars at least once a year and once a year oil the rust repellent oil latches.
****•It is obliged to check the bars connections after installation by using reasonable force near each of the bars latch and make sure there is no movement or cracks near the clasp. When in doubt it is required to ask an expert (building engineer) to check the strength of connections.

 

Limitation of Liability:
A. Installation of the bars by the customer constitutes his consent to the terms specified below. The customer is not entitled to any action against the manufacturer except those specified below.
B. In the case of a manufacturing defect or material of the bars, the company’s warranty is for repair and / or replacement of the bars according to the company's choice. The customer is not entitled in any case to any monetary compensation which is higher than the cost price of the bars.
C. The company shall not be responsible for direct financial damages and / or consequential damages that were caused to the customer by the use of bars.
D. The Company shall not be liable for any damages caused by faulty installation or defect in the wall or in the window where the bar was installed.
E. The company’s liability is provided subject to a 7 days’ notice, from the day of the defect discovery.

האתר עוצב ונבנה ע”י web4all חברה לבניה וקידום אתרים

כל הזכויות שמורות לטף סורג בע"מ